Radiator Cooling Fan Motor: Testing and Inspection
COOLING FAN MOTOR INSPECTION [MZR 1.5]
Part Inspection
1. Verify that the battery is fully charged. Testing and Inspection
2. Disconnect the cooling fan motor connector (4 terminals).
3. Install a tester and battery to the cooling fan motor connector (4 terminals) as shown in the figure.
4. Verify that the fan motor operates smoothly at the standard current.
- If there is any malfunction, replace the applicable part.
Cooling fan motor standard current [12 V]
- 7.4-11.4 A