Radiator Cooling Fan Control Module: Testing and Inspection
FAN CONTROL MODULE INSPECTION [MZI 3.7 V6]
1. Connect the M-MDS to the DLC-2.
2. Start and warm up the engine.
3. Monitor the engine coolant temperature with the M-MDS.
4. Measure the voltage at terminal A of the fan control module connector (2 terminals) as shown in the table.
- If not within the specification, inspect the input signals from the following parts.
- Cylinder Head Temperature (CHT) sensor
- Refrigerant pressure switch (middle)
Fan control module [A/C OFF (Ambient temp. ± 5-43 °C {23-109 °F})]
Fan control module [A/C ON (Ambient temp. ± 1-43 °C {31-109 °F})]
5. If all the above parts are normal, replace the fan control module.