Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oscilloscope Patterns and Waveforms

CMP sensor signal
(+)




PCM terminals
- CMP sensor (left bank): 2AA (+)-body ground (-)
- CMP sensor (right bank): 2AD (+)-body ground(-)

Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range

Vehicle condition
- Idle after warm up (no load)

(-)




PCM terminals
- CMP sensor (left bank): 2AB (+)-body ground (-)
- CMP sensor (right bank): 2AE (+)-body ground(-)

Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range

Vehicle condition
- Idle after warm up (no load)