Oscilloscope Patterns and Waveforms
CMP sensor signal(+)
PCM terminals
- CMP sensor (left bank): 2AA (+)-body ground (-)
- CMP sensor (right bank): 2AD (+)-body ground(-)
Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range
Vehicle condition
- Idle after warm up (no load)
(-)
PCM terminals
- CMP sensor (left bank): 2AB (+)-body ground (-)
- CMP sensor (right bank): 2AE (+)-body ground(-)
Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range
Vehicle condition
- Idle after warm up (no load)