Oscilloscope Patterns and Waveforms
Inspection Using An Oscilloscope (Reference)HO2S (front) signal
PCM terminals
- 1AB (+) - 2H (-)
Oscilloscope setting
- 0.1 V/DIV (Y), 400 ms/DIV (X), DC range
Vehicle condition
- Idle after warm up (engine speed approx. 700 rpm, no load, P/S off, A/C off)
HO2S (front) heater control signal PCM terminals
- 4A (+) - 1C (-)
Oscilloscope setting
- 4 V/DIV (Y), 200 ms/DIV (X), DC range
Vehicle condition
- Idle after warm up (engine speed approx. 700 rpm, no load, P/S off, A/C off)