Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Variable Air Duct (VAD) Control Solenoid Valve Inspection

VARIABLE AIR DUCT (VAD) CONTROL SOLENOID VALVE INSPECTION

1. Remove the VAD control solenoid valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)







2. Inspect airflow between the ports under the following conditions.
- If not as specified, replace the VAD control solenoid valve.
- If as specified, carry out the "Circuit Open/Short Inspection".

Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION.)




2. Inspect the given wiring harness for open or short circuit (continuity check).

Open circuit
- If there is no continuity, there is an open circuit. Repair or replace the harness.
- VAD control solenoid valve terminal B (harness-side) and PCM terminal 4C
- VAD control solenoid valve terminal A (harness-side) and main relay terminal C (harness-side)

Short circuit
- If there is continuity, there is a short circuit. Repair or replace the harness.
- VAD control solenoid valve terminal B (harness-side) and body GND
- VAD control solenoid valve terminal A (harness-side) and power supply.