Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oscilloscope Patterns and Waveforms

Inspection Using An Oscilloscope (Reference)




OCV control signal
PCM terminals

- 4M (+) - 1C (-)

Oscilloscope setting
- 2 V/DIV (Y), 0.8 ms/DIV (X), DC range

Vehicle condition
- Idle after warm up (engine speed approx. 700 rpm, no load, P/S off, A/C off)