Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oscilloscope Patterns and Waveforms

Inspection Using An Oscilloscope (Reference)

CMP sensor signal




(+)
PCM terminals

2J(+) - 2H(-)

Oscilloscope setting
- 1 V/DIV (Y), 10 ms/DIV (X), DC range

Vehicle condition
- Idle after warm up (engine speed approx. 650 rpm, no load, P/S off, A/C off)




(-)
PCM terminals

- 2M(+) - 2H(-)

Oscilloscope setting
- 1 V/DIV (Y), 10 ms/DIV (X), DC range

Vehicle condition
- Idle after warm up (engine speed approx. 650 rpm, no load, P/S off, A/C off)