With 2.5L Engine
GENERATOR REMOVAL/INSTALLATION WITH (KL)2.5L1. Remove the charge air cooler.
2. Remove in the order indicated in the table.
3. Install in the reverse order of removal.
CAUTION:
- Reversing the battery connections or using high-voltage testers will damage the rectifier.
- Do not start the engine while the connector is disconnected from terminals L and S. It can damage the generator.
- Disconnecting generator terminal B before disconnecting the negative battery cable can damage the generator harness and connector.
NOTE: Battery positive voltage is always present at generator terminal B while the battery cable connected.
A/C Compressor Removal Note
- With the pipe still connected, position the A/C compressor away from the generator for easy access to the generator.
Generator Removal Note
- Remove the generator from under the vehicle.