Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

System Specifications

Charging System Specifications
Battery
Open Circuit Voltage Above 12.4 V
Test Load Chart
Battery Load (A)
55D23L 180
75D23L 195
80D26L 195
Battery Voltage With Load
Approximate Battery Temperature Minimum Voltage (V)
21 degrees C (70 degrees F) 9.6
15 degrees C (60 degrees F) 9.5
10 degrees C (50 degrees F) 9.4
4 degrees C (40 degrees F) 9.3
Charging Current
Battery Type (5 Hour Rate) Slow Charge (A) Quick Charge (A)
55D23L (48) 4.5-5.5 30
75D23L (52) 5.0-6.0 35
80D26L (55) 5.5-6.5 35
Battery Positive Voltage Above 12.4 V
Generator
Voltage at Terminal L
Ignition Switch ON Approximately 1.0 V
Idle 13.0-14.0 V
Standard Voltage
Terminal Ignition Switch: ON (V) Idle (V)
B B+
B+: Battery Positive Voltage
B+
B+: Battery Positive Voltage
L Approximately 1.0 V Approximately 1.0 V less than B+
S B+
B+: Battery Positive Voltage
B+
B+: Battery Positive Voltage
IG B+
B+: Battery Positive Voltage
B+
B+: Battery Positive Voltage
Standard Current (Referance)
The values are measured with the battery fully charged. As the battery discharges, the current becomes greater.
Electrical Load Idle 2,000 RPM
OFF Approximately 14 A Approximately 15 A
ON
When the measuring condition is "electrical load ON", turn all the following electrical systems on. Headlights (high Beam). A/C Max. Brake Light Cooling Fan Condenser Fan
Approximately 70 A Approximately 81 A