Transaxle Range Switch Inspection
Transaxle Range Switch Inspection [GF4A-EL]Inspection Of Operation
1. Verify that the starter operates only with the ignition switch at the START position and the selector lever in P and N positions.
2. Verify that the back-up lights illuminate when shifted to R position with the ignition switch in the ON position.
- If not as specified, inspect the transaxle range switch.
Inspection of Continuity
1. Disconnect the negative battery cable.
2. Remove the resonance chamber, fresh-air duct, and air cleaner component.
3. Disconnect the transaxle range switch connector.
4. Inspect continuity of the transaxle range switch.
- If not as specified, replace or adjust the transaxle range switch.
5. Connect the transaxle range switch connector.
6. Install the air cleaner component, fresh-air duct, and resonance chamber.
7. Connect the negative battery cable.