Steering Column Relay: Testing and Inspection
Tilt Relay InspectionCONTINUITY INSPECTION
- Disconnect and inspect the connectors between the tilt relay to the circuit breaker, CPU, tilt motor, and ground.
AUTO-TILT STEERING COLUMN TILT-UP CONDITION
1. While connecting battery positive terminal to terminal D, and battery negative terminal to B, inspect continuity between terminal H and terminal A of the tilt relay side connector.
2. If not as specified, replace the tilt relay.
AUTO-TILT STEERING COLUMN TILT-DOWN CONDITION
1. While connecting battery positive terminal to terminal D, and battery negative terminal to terminal J, check for continuity between terminal H and terminal I of the tilt relay side connector
2. If not as specified, replace the tilt relay.
3. Tilt Relay OFF Condition, UP Side
4. Inspect continuity between terminal A and terminal C of the tilt relay side connector.
5. If there is no continuity, replace the tilt relay.
6. Tilt Relay OFF Condition, DOWN Side
7. Inspect continuity between terminal I and terminal C of the tilt relay side connector.
8. If there is no continuity, replace the tilt relay.