Fail-Safe Relay
1. Measure resistance between terminals C and D of ABS relay connector.
^ Resistance: 60-100 Ohms.
2. Check for continuity between terminals A and E, and between B and E.
NOTE: There should be continuity between A and E. There should not be continuity between B and E.
3. Apply 12 V between terminals D and C. Check for continuity between terminals B and E and between A and E.
NOTE: There should be continuity between B and E. There should not be continuity between A and E.
4. If not as specified, replace the ABS relay.