No. 2 Keyless Entry System Does Not Function (Trunk)
Flowchart No.2 Symptom Keyless entry system does not function (Trunk)
Possible cause
^ Burnt ROOM 15A fuse
^ Burnt DOOR LOCK 30A fuse
^ Damaged keyless unit
^ Damaged CPU
^ Damaged transmitter
^ Damaged trunk lid opener relay
^ Damaged trunk lid actuator
^ Open or short circuit in wiring harness
^ Poor connection of connector
Step 1
Fuse Inspection:
Action Chart:
Check the ROOM 15A fuse in the fuse block.
Step 2
1. Open the trunk lid.
Voltmeter Connection:
Action Chart:
2. Measure the voltage at the (L/R) terminal wire of the keyless unit connector in the trunk compartment
Step 3
1. Disconnect the keyless unit connector.
Ohmmeter Connection:
Action Chart:
2. Check for continuity between the (B) terminal wire and ground.
Step 4
Voltmeter Connection:
Action Chart:
Measure the voltage at terminal wire 2R (R/Y) of the CPU connector.
Step 5
Voltmeter Connection:
Action Chart:
Measure the voltage at terminal E (R/Y) wires of the keyless unit connectors.
Step 6
Fuse Inspection:
Action Chart:
Check the DOOR LOCK 30A fuse in the fuse block.
Step 7
1. Remove the trunk side trim.
Voltmeter Connection:
Action Chart:
2. Measure the voltage at the (W/G) terminal wire of the trunk lid opener relay connector.
Step 8
Voltmeter Connection:
Action Chart:
Measure the voltage at the (L/R) terminal wire of the trunk lid opener relay connector.
Step 9
Voltmeter Connection:
Action Chart:
Measure the voltage at the (LG/R), (G/W) terminal wire of the trunk lid opener relay connector, with the transmitter by pressing the TRUNK button.
Step 10
Voltmeter Connection:
Action Chart:
Measure the voltage at terminal wire 20 (LG/R) of the CPU connector.
Step 11
Voltmeter Connection:
Action Chart:
Measure the voltage at the (LG/R) terminal wire of the trunk lid actuator connector.
Step 12
1. Disconnect the trunk lid actuator connector.
Ohmmeter Connection:
Action Chart:
2. Check for continuity between the (B) terminal wire and ground.