With Automatic Transaxle
PRIMING FUEL SYSTEMAfter the fuel pressure has been released for repairs or inspection, the system must be primed to avoid excessive cranking when the engine is first started. Follow the steps below.
Breakout Box:
1. Connect PCM terminal No.80 and a ground by using a jumper wire and the SST.
2. Turn the ignition switch to ON for approx. 10 sec. and check for fuel leaks.
3. Turn the ignition switch to OFF and disconnect the jumper wire.