Accelerator Pedal: Testing and Inspection
ACCELERATOR CABLE INSPECTION / ADJUSTMENT1. Verify that the throttle valve is in the closed throttle position.
2. Measure the free play of the accelerator cable.
Free play: 1.5-4.0 mm (O.06-O.16 in)
3. If not as specified, adjust the cable free play by turning stopper (B) while pressing lock button (A) with the closed throttle position.
4. Reset the cable lock.