With SST-New Generation Star Tester
Using SST-New Generation Star Tester (NGS)1. Connect the SST to the data link connector-2.
2. Select the PID/DATA MONITOR AND RECORD function of NGS.
3. Select "HO2SRF", "HO2SRR", "HO2SLF" and "HO2SLR" on the NGS display. NGS measures and shows the voltage.
Specification:
4. If not as specified, inspect following:
- Intake-air system
- Fuel system
- On-Board diagnosis system
If there systems are OK, replace the heated oxygen sensor.
Inspection
Heater
1. Disconnect the heated oxygen sensor connector.
Front HO2S:
Rear HO2S:
2. Measure the resistance between heated oxygen sensor terminals B and C by using an ohmmeter.
Specification: Approx. 6 ohms 20°C (68°F)
3. If not as specified, replace the heated oxygen sensor.