Component Tests and General Diagnostics
View: By-pass Air Control (BAC) Valve Sub-components:
INSPECTION
1. Disconnect the idle air control valve connector.
View: Idle Air Control Valve Connector:
2. Connect an ohmmeter between the terminals of the idle air. control valve and measure the resistance.
Resistance at 20°C (68°F): 11.5 +/- 0.8 Ohms