Pressure Control Solenoid Valve Output Duty

PRESSURE CONTROL SOLENOID VALVE OUTPUT DUTY

Inspection




1. Connect the (+) terminal of a dwell meter to terminal 2N at the transaxle control module and the (-) terminal to a ground.
Set the dwell meter selector to the 4 cylinder position.
2. Engage the parking brake and use wheel chocks at the front and rear of the wheels.
3. Start the engine.
4. Depress the brake pedal firmly.
5. Shift the selector lever to D range.

Note: The dwell meter indicates the OFF duty ratio.




6. Verify the duty ration by depressing and releasing the accelerator pedal.

Dwell Angle/Duty Ratio Relationship




7. Depress the accelerator pedal slowly and verify the duty ratio charges as shown in the graph.




8. If not as specified, check the transaxle control module and pressure control solenoid valve.