A/C Cut-Off Control Inspection
SYSTEM TEST1. Turn the ignition switch to ON.
2. Turn the blower switch and air conditioning switch ON.
3. Turn the ignition switch to START and verify that the condenser fan stops for approx. 3 Sec.
Note: The magnetic clutch and the additional fan operate together.