Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Ignition Cable: Testing and Inspection




INSPECTION
1. Measure resistance of the high-tension leads.
2. If not as specified, replace the high-tension lead set.

Specification: 16 k Ohms per 1m (3.28 ft)