With Manual Transaxle (MTX)
INSPECTION
1. Verify that the main relay clicks when the ignition switch is turned ON and OFF.
2. Apply battery positive voltage (B+) to terminal E and ground terminal A of the relay.
3. Check continuity of the relay as shown.
NOTE: B+ is Battery positive voltage.
4. If not as specified, replace the main relay.