Operation Inspection
InspectionFuel Pump Operation
1. Connect the data link connector terminals F/P and GND with a jumper wire.
2. Remove the fuel filler cap.
3. Turn the ignition switch ON.
4. Listen for operational sound of the fuel pump at the filler inlet.
5. Install the fuel filler cap.
6. If no sound was heard, measure the voltage the fuel pump connector wire W/R.
Voltage: Battery positive voltage
7. If not correct, check the fuel pump relay and its circuits.
8. If the voltage is normal, check for continuity between fuel pump connector A and B.
9. If there is no continuity, replace the fuel pump.