Thermostatic Expansion Valve Manifold and Tube Assembly
Thermostatic Expansion Valve Manifold and Tube Assembly
Removal and Installation
1. Recover the refrigerant.
2. Remove the 4 cross vehicle beam nuts and remove the beam.
- To install, tighten to 30 Nm (22 lb-ft).
3. Remove the Evaporative Emission (EVAP) canister purge valve.
4. Remove the evaporator outlet line fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
5. Remove the evaporator inlet line fitting bracket bolt.
6. Remove the evaporator inlet line fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
7. Remove the Thermostatic Expansion Valve (TXV) manifold and tube bracket bolt.
- To install, tighten to 9 Nm (80 lb-in).
8. Remove the TXV fitting bolt and disconnect the fitting.
- Discard the O-ring seals.
- To install, tighten to 8 Nm (71 lb-in).
9. Remove the TXV manifold and tube assembly.
10. To install, reverse the removal procedure.
- Install new gasket seals and O-ring seals.
- Add the correct amount of clean PAG oil to the refrigerant system.
11. Evacuate, leak test and charge the refrigerant system.