Exhaust Manifold - RH
Exhaust Manifold - RHMaterial:
Removal
1. Remove the RH catalytic converter.
2. Disconnect the RH heated oxygen sensor (HO2S) electrical connector.
3. Remove the 6 nuts and the RH exhaust manifold.
^ Discard the nuts and gasket.
4. Clean and inspect the RH exhaust manifold.
5. Remove and discard the 6 RH exhaust manifold studs.
6. CAUTION: Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These may cause scratches and gouges resulting in leak paths. Use a plastic scraper to clean the sealing surfaces.
Clean the exhaust manifold mating surface of the cylinder head with metal surface prep. Follow the directions on the packaging.
Installation
1. Install 6 new RH exhaust manifold studs.
^ Tighten to 12 Nm (9 ft. lbs.).
2. Using a new gasket, install the RH exhaust manifold and 6 new nuts.
^ Tighten in the sequence shown to 20 Nm (15 ft. lbs.).
3. Connect the RH HO2S electrical connector.
4. Install the RH catalytic converter.