System Specifications
| Capacity | 11.3L | |
| Cooling fan MAX speed | 2 300 +/- 100 rpm | |
| Cooling fan MAX pressure output | 1,200 psi | |
| Cooling fan operating pressure | 900 psi | |
| Cooling fan operating flow rate | 4.0 +/- 0.25 gpm | |
| Coolant mixture with water Motorcraft Premium Gold Engine Coolant VC-7-A or equivalent meeting Ford specification WSS-M97B51 -Al (yellow in color). Do not mix coolant types. | 50% | |
| Pressure relief cap opening pressure | 16 psi | |
| Water thermostat start to open temperature | 192-199° Farenheit | |
| Water thermostat full open temperature | 219° Farenheit | |
| Engine appearance cover bracket | 89 inch lbs. | |
| Lower radiator hose | 10 ft. lbs. | |
| Water outlet adapter | 8 ft. lbs. | |
| Thermostat housing | 8 ft. lbs. | |
| Coolant outlet pipe | 8 ft. lbs. | |
| Water pump | Stage 1 | 71 in.lbs. |
| Stage 2 | 90° | |
| Upper radiator support brackets | 89 inch lbs. | |
| Receiver/drier bracket | 8 ft. lbs. | |
| Auxiliary water pump | 89 inch lbs. | |
| Hydraulic cooling fan high pressure line | 15 ft. lbs. | |
| Hydraulic cooling fan high pressure line bracket | 71 inch lbs. | |
| Condenser-to-radiator bolts | 89 inch lbs. | |
| Hydraulic cooling fan pump | 18 ft. lbs. | |
| Hydraulic cooling fan high pressure line support bracket | 10 ft. lbs. | |
| Cross vehicle support | 15 ft. lbs. | |
| Degas bottle | 53 inch lbs. | |
| Engine fill cap | 80 inch lbs. | |
| Water pump pulley | Stage 1 | 89 in.lbs. |
| Stage 2 | 45° |