Leak Detection Valve: Service and Repair
REMOVAL1. Raise and support the vehicle. For additional information, refer to Maintenance/Service and Repair.
2. Position a jack stand under the differential.
3. Remove the bolt.
4. Lower the differential to access the canister vent solenoid as necessary.
5. Remove the canister vent solenoid.
1 Disconnect the connector.
2 Disconnect the hose.
3 Remove the canister vent solenoid.
INSTALLATION
1. To install, reverse the removal procedure.
^ Carry Out a leak test. For additional information, refer to Evaporative Emission System Leak Test. Evaporative Emission System Leak Test
^ Carry out the evaporative emission repair verification drive cycle. For additional information, refer to Evaporative Emission Repair Verification Drive Cycle. Service and Repair
NOTE: Lubricate the O-ring seals with MERPOL(R) or equivalent meeting Ford specifications ESE-M99B144-B.