Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Leak Detection Valve: Service and Repair

REMOVAL
1. Raise and support the vehicle. For additional information, refer to Maintenance/Service and Repair.







2. Position a jack stand under the differential.







3. Remove the bolt.







4. Lower the differential to access the canister vent solenoid as necessary.







5. Remove the canister vent solenoid.
1 Disconnect the connector.
2 Disconnect the hose.
3 Remove the canister vent solenoid.

INSTALLATION
1. To install, reverse the removal procedure.
^ Carry Out a leak test. For additional information, refer to Evaporative Emission System Leak Test. Evaporative Emission System Leak Test
^ Carry out the evaporative emission repair verification drive cycle. For additional information, refer to Evaporative Emission Repair Verification Drive Cycle. Service and Repair

NOTE: Lubricate the O-ring seals with MERPOL(R) or equivalent meeting Ford specifications ESE-M99B144-B.