Flushing
Special Tools:
Special Tool
1. Use a Torque Converter/Oil Cooler Cleaner to clean and flush the torque converter.
NOTE: When the transaxle has been repaired for internal damage the torque converter must be cleaned using a mechanically agitated cleaner.
2. After flushing, drain the remainder of the solvent.
3. Add 1.9 liter (2 quart.) of clean transmission fluid to the torque converter and agitate by hand.
4. Thoroughly drain the torque converter.