GA6 Component Check Actuate to Firm Position -- Pin 4
^ Use a 12 volt power supply and connect negative lead to actuator 3 and positive lead to Pin 4 for 1 to 2 seconds. This procedure should drive actuator to FIRM position. After this has been done remove power supply leads.
^ Using an analog ohmmeter, measure the resistance across actuator Pin 1 and Pin 2.
^ Ohmmeter reading is:
10,000 ohms or greater -- GO to GA15.
5 ohms or less -- GO to GA7.