Condenser HVAC: Service and Repair
Fig. 2 Spring lock coupling disconnect & connect:
Fig. 3 Condenser assembly removal:
1. Discharge and evacuate refrigerant from system. Refrigerant Recovery
2. Remove battery.
3. Disconnect the two refrigerant lines on right side of radiator (first illustration).
4. Remove four bolts attaching condenser to radiator support, then the condenser (second illustration).
5. Reverse procedure to install. Use new O-rings lubricated with refrigerant oil.
6. Evacuate, charge and leak test system. Refrigerant Recovery Evacuation and Charging