Air Injection Pump Relay: Service and Repair
17.25.06 Relay - Secondary Air Injection Pump (SAI)
Before disconnecting the battery, ensure all text and cautions in the battery disconnection section are observed.
Remove
1. Disconnect battery earth lead.
2. Remove 10 Allen screws securing 'E' box cover and remove cover.
3. Release SAI relay from 'E' box and disconnect multiplug.
Refit
1. Position SAI relay, connect multiplug and fit relay to 'E' box.
2. Fit 'E' box cover and tighten Allen screws to 2 Nm (1.5 lbf.ft).
3. Connect battery earth lead.