Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Harness - Evaporator/Blower Motor Assembly - Rear

Harness - Evaporator/Blower Motor Assembly - Rear

Remove
1. Remove evaporator/blower motor assembly.





2. Remove screw securing harness retaining clip to casing.
3. Release harness clip from casing tag.
4. Disconnect 4 relay multiplugs.
5. Disconnect 2 Lucars from thermostat.





6. Disconnect multiplug from ECU.
7. Release control valve solenoid multiplug from mounting bracket and disconnect multiplug.
8. Disconnect multiplug from blower motor.
9. Disconnect multiplug from resistor.
10. Remove harness.

Refit
11. Fit harness and route into position.
12. Connect multiplug to resistor.
13. Connect multiplug to blower motor.
14. Connect control valve solenoid multiplug and secure multiplug to mounting bracket.
15. Connect multiplug to ECU.
16. Connect Lucars to thermostat.
17. Connect multiplugs to relays.
18. Secure harness clip to casing tag.
19. Fit screw securing harness retaining clip to casing.
20. Fit evaporator/blower motor assembly.