Variable Valve Timing Solenoid: Service and Repair
Variable Camshaft Timing (VCT) Oil Control Solenoid
Removal
1 Disconnect the battery ground cable. For additional information, refer to Battery Disconnect and Connect Battery Disconnect and Connect
2 Remove the valve cover. For additional information, refer to Valve Cover LH Valve Cover LH
3
NOTE:
Left-hand shown, right-hand similar.
Remove the variable camshaft timing (VCT) oil control solenoid.
Installation
1 To install, reverse the removal procedure.
- Tighten to 10 Nm.
2
NOTE:
For NAS vehicles only.
If required, carry out a short drive cycle.For additional information, refer to Powertrain Control Module (PCM) Short Drive Cycle Self-Test