G189073T4
G189073t4: CHECK FOR KEY INTERLOCK ACTION1. Check for continuity between Pin 3 and Pin 4 of the ignition switch lock cylinder.
^ Is the circuit continuous?
- > Yes
Install a new J-gate. TEST the system for normal operation.
- > No
Install a new ignition switch lock cylinder. TEST the system for normal operation.