PINPOINT TEST G531332p20
Pinpoint Tests
PINPOINT TEST G531332p20 : BATTERY POWER SUPPLY VOLTAGE MALFUNCTION
G531332t79 : CHECK THE BATTERY POWER SUPPLY TO THE ECM
1. Disconnect the ECM electrical connector, PI300.
2. Measure the voltage between:
ECM connector PI300, Battery
harness side
Pin 54 Negative terminal
- Is the voltage greater than 10 volts?
->YES
Recheck the DTCs.
->NO
REPAIR the battery power supply circuit. This circuit includes fuse 17 of the front power distribution. CLEAR the DTC. TEST the system for normal operation.