D2: Check Harness Continuity (Sensor Input)
Disconnect EM011 and EM010.
Remove FTP sensor connector FP001.
Measure resistance between EM011/007 and FP001/002.
- Is the resistance < 0.5 ohms?
Yes
GO to D3 D3: Check Harness Continuity (Sensor Supply Ground)
No
Inspect harness/connectors EM011, FP001, EM003, FC001, BT004 and BT005 for damage, corrosion, bent/pushed back pins. Repair as necessary and test the system for normal operation.