B7: Check Injector Circuit Continuity
With EM015 disconnected, measure the resistance, as appropriate, between
EM015/007 and IJ003/001
EM015/017 and IJ004/001
EM015/016 and IJ005/001
EM015/006 and IJ006/001
EM015/018 and IJ007/001
EM015/005 and IJ008/001
EM015/004 and IJ009/001
EM015/015 and IJ0010/001
- Is the resistance < 0.5 ohms?
Yes
GO to B8 B8: Check Injector Ground
No
Inspect the harness/connector EM015, PI001/030 to PI001/038, IJ001/002 to IJ001/005, IJ002/002 to IJ002/005 or IJ003 to Job. Repair as necessary and test the system for normal operation.