Feed Hose
- Drain the engine oil.- Remove the splash panel securing screws.
Oil Cooler Connections:
- Disconnect the supply hose union (2).
NOTE: Two spanners, one on the oil cooler union the other on the hose union, must be used.
- Disconnect the supply hose from the oil cooler (1).
- Plug all broken connections to prevent dirt ingress.
- Connect the replacement supply hose to the oil cooler.
- Connect the supply hose union.
- Refit the lower splash panel.
- Refit the sump plug, using a new washer and refill the engine with clean oil.
TORQUE FIGURES
Oil cooler pipes 54-6O Nm
Sump drain plug 15-18 Nm