Air Cleaner Housing: Service and Repair
AIR CLEANER AND AIR DUCTExploded View EM-17:
Removal and Installation
REMOVAL
1. Remove engine room cover (RH and LH).
2. Remove air duct (inlet).
3. Disconnect mass air flow sensor harness connector.
4. Disconnect PCV hose.
5. Remove air cleaner case/mass air flow sensor assembly and air duct/air hose disconnecting their joints.
^ Add marks as necessary for easier installation.
6. Remove mass air flow sensor from air cleaner case, as necessary.
CAUTION:
Handle mass air flow sensor with the following cares.
^ Do not shock it.
^ Do not disassemble it.
^ Do not touch its sensor.
INSTALLATION
Note the following, and install in the reverse order of removal.
^ Align marks. Attach each joint. Screw clamps firmly.