Inspection 11: RAS Warning Lamp Harness
Inspection 11: RAS Warning Lamp Harness1. CHECK RAS WARNING LAMP SIGNAL
Turn ignition switch ON, and then check voltage between RAS control unit harness connector and ground.
OK or NG
OK >> Perform self-diagnosis. Refer to STC-23, "Self-Diagnosis". Self-Diagnosis
NG >> GO TO 2.
2. CHECK RAS WARNING LAMP HARNESS
1. Turn ignition switch OFF, disconnect RAS control unit harness connector and combination meter harness connector.
2. Check continuity between the following terminals.
- RAS control unit harness connector B136 terminal 26 and combination meter harness connector M19 terminal 36.
Continuity should exist.
3. Check continuity between RAS control unit harness connector and ground.
- RAS control unit harness connector B136 terminal 26 and ground.
Continuity should exist.
OK or NG
OK >> GO TO combination meter power supply circuit.
NG >> Harness between RAS control unit and combination meter open or shorted. Repair or replace harness.