Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

CONSULT-II Inspection Procedure

CONSULT-II INSPECTION PROCEDURE

CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.

1. Turn ignition switch "OFF".




2. Connect "CONSULT-II" and "CONSULT-II CONVERTER" to the data link connector (1).

3. Turn ignition switch "ON".




4. Touch "START (NISSAN BASED VHCL)".




5. Touch "PRECRASH SEATBELT".
If "PRECRASH SEATBELT" is not indicated, refer to "CONSULT-II Data Link Connector (DLC) Circuit".




6. Select diagnosis mode. "SELF-DIAG RESULTS", "DATA MONITOR", "CAN DIAG SUPPORT MNTR" and "ECU PART NUMBER" are available.