Vehicle Immobilizer System
CONSULT-IICONSULT-II INSPECTION PROCEDURE
1. Turn ignition switch OFF.
2. Insert IVIS (NATS) program card into CONSULT-II.
Program card: NATS (AEN02C)
3. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
4. Turn ignition switch ON.
5. Touch "START".
6. Touch "OTHER".
7. Select "NATS V.5.0".
If "NATS V5.0" is not indicated, go to GI-38, "CONSULT-II Data Link Connector (DLC) Circuit". Data Link Connector Schematic
8. Perform each diagnostic test mode according to each service procedure.
For further information, see the CONSULT-II Operation Manual
NATS-IVIS/NVIS.