Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

How to Alternate Diagnosis Mode

Meter/Gauges Operation and Odo/Trip Meter

HOW TO ALTERNATE DIAGNOSIS MODE
1. Turn the ignition switch ON, and switch the odo/trip meter to "trip A" or "trip B".

NOTE: If the diagnosis function is activated with the trip meter A displayed, the mileage on the trip meter A will indicate 0000.0 miles, but the actual trip mileage will be retained. (Trip B operates the same way.)

2. Turn ignition switch OFF.
3. While pushing the odo/trip meter switch, turn ignition switch ON again.
4. Check that the trip meter displays "0000.0".
5. Push the odo/trip meter switch at least 3 times. (Within 7 seconds after the ignition switch is turned ON.)




6. All the segments on the odo/trip meter and A/T indicator illuminate, and simultaneously the low-fuel warning lamp indicator illuminates. At this time, the unified meter control unit is turned to diagnosis mode.

NOTE: If any of the segments is not displayed, replace the combination meter.