12 "Shift Position Error"
Inspection 12 When "SHIFT POSITION ERROR" Appears in self-Diagnostic results Display (A/T Models)Inspection Procedure
1. CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
Does "SHIFT POSITION ERROR" appear in self-diagnostic results display?
YES >> GO TO 2.
NO >> INSPECTION END
2. PERFORM DATA MONITOR
1. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector. Start engine.
2. In "DATA MONITOR" select "MAIN SIGNALS" and then check select lever position.
OK or NG
OK >> Perform VDC/TCS/ABS control unit self-diagnosis again.
NG >> GO TO 3.
3. CHECK A/T PARK/NEUTRAL POSITION SWITCH
Perform the A/T park/neutral position switch inspection.
Do any self-diagnosis items appear?
YES >> Repair the indicated items and perform VDC/TCS/ABS control unit self-diagnosis again.
NO >> Perform VDC/TCS/ABS control unit self-diagnosis again.