Intake Door Motor
* Manual Air Conditioning System *TROUBLE DIAGNOSIS PROCEDURE FOR INTAKE DOOR
Inspection Flow:
COMPONENT DESCRIPTION
Intake Door Motor
The intake door motor is attached to the intake unit. It rotates so that air is drawn from inlets set by each mode switches. Motor rotation is conveyed to a lever which activates the intake door. RECIRCULATION switch is canceled by MODE switch in DEF and D/F modes.
DIAGNOSTIC PROCEDURE
Step 1 - 2:
Step 3 - 5:
Step 6 - 7:
INTAKE DOOR MOTOR CIRCUIT
CONTROL LINKAGE ADJUSTMENT
Intake Door Motor
1. Install intake door motor on intake unit.
Ensure that the intake door motor lever is fitted into the slit portion of intake door link.
2. Connect the intake door motor harness connector.
3. Turn ignition switch to "ON" position.
4. Check that intake door operates properly when REC switch is turned ON and OFF.