Vehicle Immobilizer System

CONSULT-II INSPECTION PROCEDURE




1. Turn ignition switch OFF.
2. Connect "CONSULT-II" to Data link connector.




3. Insert IVIS (NATS) program card into CONSULT-II.
Program card
NATS (UEN99A)

4. Turn ignition switch ON.
5. Touch "START".




6. Select "NATS V.5.0".




7. Perform each diagnostic test mode according to each service procedure.

For further information, see the CONSULT-II Operation Manual, IVIS/NVIS.




CONSULT-II DIAGNOSTIC TEST MODE FUNCTION

NOTE:
- When any initialization is performed. All ID previously registered will be erased and all IVIS (NATS) ignition keys must be registered again.
- The engine cannot be started with an unregistered key. In this case, the system may show "DIFFERENCE OF KEY" or "LOCK MODE" as a self-diagnostic result on the CONSULT-II screen.
- In rare case, "CHAIN OF ECM-IMMU" might be stored as a self-diagnostic result during key registration procedure, even if the system is not malfunctioning.