Diode: Testing and Inspection
DIODE CHECK- Check continuity using an ohmmeter.
- Diode is functioning properly if test results are as shown in the diagram.
NOTE: Specifications may vary depending on the type of tester. Before performing this inspection, be sure to refer to the instruction manual for the tester to be used.
- Diodes for warning lamps are built into the combination meter printed circuit.