Service Specifications
| Drive Shaft To Oil Pump Cover And Housing Clearance (C) | 0.024 - 0.069 Millimeter (mm) |
| Driven Gear To Driven Shaft Clearance (F) | 0.025 - 0.064 Millimeter (mm) |
| Drive And Driven Gear To Oil Pump Housing Axial Clearance (G) | 0.08 - 0.130 Millimeter (mm) |
| Drive And Driven Gear To Oil Pump Housing Radial Clearance (H) | 0.125 - 0.245 Millimeter (mm) |
| Regulator Valve to Oil Pump Clearance | 0.040 - 0.097 Millimeter (mm) |