Procedure 2 Inspecting Malfunctioning Parts - CONSULT Scan Tool

Inspecting SRS malfunctioning parts by using CONSULT - Diagnosis mode






1. Turn ignition switch "OFF".
2. Connect "CONSULT" to Data link connector.






3. Turn ignition switch "ON".
4. Touch "START".






5. Touch "AIRBAG".






6. Touch "SELF-DIAG [CURRENT]".






7. Diagnostic codes are displayed on "SELF-DIAG [CURRENT]".






If no malfunction is detected on "SELF-DIAG [CURRENT]" even though malfunction is detected in "SRS Operation Check", go to DIAGNOSTIC PROCEDURE 4, to diagnose the following cases:
- Self-diagnostic result "SELF-DIAG [PAST]" (previously stored in the memory) might not be erased after repair.
- The SRS system malfunctions intermittently.

8. Touch "PRINT".
9. Compare diagnostic codes to "CONSULT Diagnostic Code Chart".
10. Touch "BACK" key of CONSULT until "SELECT SYSTEM" appears in order to return to User mode from Diagnosis mode, then turn off CONSULT
11. Turn ignition switch "OFF", then disconnect CONSULT and both battery cables.
12. Repair the system as outlined by the "Repair order" in "CONSULT Diagnostic Code Chart", that corresponds to the self-diagnostic result. For replacement procedure of component parts.
13. After repairing the system, go to DIAGNOSTIC PROCEDURE 3, for final checking.
CONSULT can only show one seat belt pre-tensioner malfunction as self-diagnosis result at a time. Check self-diagnosis result with CONSULT whether other malfunctions are detected after repairing one seat belt pre-tensioner malfunction.











CONSULT Diagnostic Code Chart ("SELF-DIAG [CURRENT]")