IVMS Operation Procedure
Diagnostic Items Application
Diagnostic Items Description
Consult Inspection Procedure
1. Turn ignition switch "OFF".
2. Connect "CONSULT" to the data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "IVMS".
6. Perform each diagnostic item according to the item application chart.
IVMS Communication Diagnosis
1. Touch "IVMS COMM DIAGNOSIS" in "IVMS-COMM CHECK".
2. Touch "START".
3. If no failure is detected, inspection is end.
If any problem code is displayed, repair/replace the system according to the IVMS communication diagnosis results.
4. Erase the diagnostic results memory.
a. Turn ignition switch "ON".
b. Touch "IVMS".
c. Touch "IVMS COMM DIAGNOSIS" in "IVMS-COMM CHECK".
d. Touch "START" for "IVMS COMM DIAGNOSIS".
e. Touch "ERASE".
Wake-Up Diagnosis
1. Touch "WAKE-UP DIAGNOSIS" in "IVMS-COMM CHECK".
2. Touch "START" for "WAKE-UP DIAGNOSIS".
3. After touching "START", turn ON switch designated on CONSULT display within 15 seconds.
4. If no failure is detected, touch "NEXT" and perform wake-up diagnosis for next LCU or touch "END". (INSPECTION END)
If any problem is displayed, replace the LCU.
If "SW DATA UNMATCH" is displayed, touch "RETEST" and perform wake-up diagnosis again.
IVMS Communication Diagnoses Results List-1
IVMS Communication Diagnoses Results List-2
IVMS Communication Diagnoses Results List-3
WORK FLOW
NOTE:
^ When LCU connectors are disconnected for more than 1 minute such as during trouble diagnoses, the "disconnected" data will be memorized by the BCM. (While BCM memorizes the "disconnected" data, IVMS communication diagnosis of CONSULT will display "PAST NO RESPONSE".) Therefore, afier reconnecting the LCU connectors, erase the memory.
^ To erase the memory, perform the procedure below.
Erase the memory with CONSULT (Refer to EL-207.) or turn the ignition switch to "OFF" position and remove 7.5 A fuse [No. [14], located in the fuse block (J/B)].
Ground Circuit Check
Power Supply Circuit Check
Data Lines Circuit Check
Data Lines Short Circuit Check